Environmental | |||||
Parameter | Min | Typical | Max | Unit | Remark |
Permanent operating temperature | -30 | 60 | °C | 55°C to 80°C must be derated. For details, see the ambient temperature and output power diagram | |
Storage temperature | -40 | 80 | °C | ||
Work Relative Humidity | 10 | 90 | % | No condensation | |
Storage RelativeHumidity | 10 | 90 | % | ||
Altitude | 3000 | M | |||
Cooling mode | Natural wind cold | ||||
Atmospheric pressure | 80 | 106 | Pa | ||
Vibration | 10-55Hz 19.6m/S²(2G),20 minutes each along X,Y and Z axis. | ||||
Shock | 49m/S²( 5G),2 0 once each X,Y and Z axis. |
Input | |||||
Parameter | Min | Typical | Max | Unit | Remark |
Input voltage range | 190 | 220 | 264 | Vac | |
Rated input voltage | 190 | 220 | 264 | Vac | |
Input voltage frequency | 47 | 50 | 63 | Hz | |
PF | / | 220Vac Full load | |||
Input shock current | 40 | A | 220Vac Full load / cold state | ||
AC input system | One-way input L、N | Support for single phase |
Basic output characteristics | |||||
Parameter | Min | Typical | Max | Unit | Remark |
Output voltage | 4.9 | 5 | 5.1 | Vdc | |
Output current | 0 | 40 | A | ||
Load regulation accuracy | ±1% | VO | Rated voltage input, full load change | ||
Voltage regulationaccuracy | ±1% | VO | |||
Regulation accuracy | ±2% | VO | Rated voltage input/full load output | ||
Power adjustment rate | ±1% | VO | Rated current output, change in full voltage range |
Ripple and noise | ≤150 | mVp-p | At full load, and during the test, a 0.1uF porcelain capacitor or gold film capacitor and a 10uF electrolytic capacitor are added to the output end, and the bandwidth of the oscilloscope is 20MHz |
Other output characteristics | ||||||
Parameter | Min | Typical | Max | Unit | Remark | |
Output Power( W) | 200 | W | ||||
Output Efficiency | ≥88 | % | 220Vac Full load | |||
Output dynamic | ±5%Vo,≤150us | 25%-50% or 50%-75% load change | ||||
Off overshoot | ±5% | Vo | ||||
Temperature Coefficient | %/℃ | Rated output voltage and output current, full range of operating temperature | ||||
Power output delay | ≤2500 | ms | Full load test at 220Vac | |||
Off overshoot | ±5% | Vo | Full voltage input range, full load output | |||
Output voltage rise time | ≤50 | ms | The rise time measured is when the output voltage rise from 10% to 90% of specified output Vout observed on the channel wave form |
Protection | |||||
Parameter | Min | Typical | Max | Unit | Remark |
Input undervoltage protection | 135 | 155 | Vac | FULL LOAD | |
Input voltage recovery point | 44 | 60 | Vac | ||
Output current limit protection point | 44 | 60 | A | Hiccup Model, Auto-recovery | |
Output short circuit protection | ≥44 | A |
Other features : | ||
Parameter | Standard/SPEC | |
Leakage current | <1.0mA(Vin=220Vac) GB8898-2001 9.1.1 | |
MTBF | MTBF≥ 50,000h | |
Odour requirements | Can not produce odors and unhealthy odors. |
Safety and insulation level | ||||
Parameter | Test conditions | Standard/SPEC | ||
Isolation voltage | Input-Output | 3000Vac/10mA/1min | No flashover, no breakdown | |
Input-PE | 1500Vac/10mA/1min | No flashover, no breakdown | ||
Output-PE | 500Vdc/10mA/1min | No flashover, no breakdown | ||
Insulation Resistance | Input-Output | DC500V | ≥10MΩ | Min |
Input-PE | DC500V | ≥10MΩ | Min | |
Output-PE | DC500V | ≥10MΩ | Min |
Mechanical characteristics | |
L *W *H | L190*W82*H30mm |
Weight( kg) | 420g |
NO. | NO. | Define. |
1 | PIN1 | NEUTRAL |
2 | PIN2 | NEUTRAL |
3 | PIN3 | LINE |
4 | PIN4 | LINE |
5 | PIN5 | EARTH |
NO. | NO. | Define. |
1 | PIN1 | GND |
2 | PIN2 | GND |
3 | PIN3 | GND |
4 | PIN4 | +5.0VDC |
5 | PIN5 | +5.0VDC |
6 | PIN6 | +5.0VDC |